91 308 38 38
Articulo JCRS: Disk halo size measured in individuals with monofocal versus diffractive multifocal intraocular lenses

Disk halo size measured in individuals with monofocal versus diffractive multifocal intraocular lenses

Disk halo size measured in individuals with monofocal versus diffractive multifocal intraocular lenses Artículo publicado en: Journal of Cataract & Refractive SurgeryNovember 2015, Volume 41, Issue 11, Pages 2417–2423Artículo original   Author: M.C. Puell Co Author:  M.J. Pérez-Carrasco, F.J. Hurtado-Ceña, L. Álvarez-Rementería   Purpose: To compare disk halo size in response to a glare source in […]

Leer más
ESCRS 2015 - Corneal biomechanical properties after DMEK surgery: a pilot study

Corneal biomechanical properties after DMEK surgery: a pilot study

Author: J. Gros-Otero Co Author:  I. Dapena, J. Martinez, C. Sanchez-Barahona, G. Bolivar, M. Teus Purpose: To study the corneal biomechanical properties measured by Corvis ST six months after DMEK surgery compared with healthy eyes. Intraocular pressure, pachymetry, first (A1) and second (A2) applanation features (time, velocity and length) and highest concavity features (time, deformation […]

Leer más
Diabetes y las enfermedades oculares

La diabetes y las enfermedades oculares

  La diabetes es un trastorno metabólico frecuente (afecta entre el 2% y 6% de la población en el mundo occidental), que se caracteriza por unos niveles de glucosa (azúcar) en sangre, de forma mantenida, por encima de los límites normales. Esta situación ocasiona daños, principalmente, a nivel de los vasos sanguíneos y de los […]

Leer más
Salud Visual durante el Embarazo

Salud Visual durante el embarazo

  Durante el embarazo se producen cambios en el cuerpo de la mujer y por tanto también en los ojos. Es importante diferenciar cambios fisiológicos de los patológicos. Tenemos que tener en cuenta que en dicho periodo se producen variaciones hormonales, metabólicas, cardiovasculares, inmunológicas, etc…   ? CAMBIOS FISIOLÓGICOS DURANTE EL EMBARAZO:   • Cambios […]

Leer más

DMAE Exudativa: Caso Clínico EYLEA

DMAE Exudativa: Caso Clínico EYLEA DMAE Exudativa: Caso Clínico from Clínica Rementería En la ponencia presentada por la Dra. Alba Coronado Toural durante una reunión de expertos en retina y polo posterior celebrada en Madrid podemos ver la evolución de un caso clínico en el que una DMAE Exudativa es tratada con inyecciones intravítreas de EYLEA. 

Leer más
Lens vacuoles during phakic intraocular lens implantation

Lens vacuoles during phakic intraocular lens implantation

Lens vacuoles during phakic intraocular lens implantation

Artículo original publicado en:
Journal of Emmetropia
Autores: Juan Gros-Otero, Inés Contreras-Martín, Jorge García-Pérez, Fran.

 

Abstract:

Lens damage during phakic intraocular lens implantation is a major complication. A case of a patient who developed lens vacuoles during toric implantable collamer lens (ICL) removal from her right eye and insertion of a new non-toric ICL due to persistent rotation of the former is presented in this work. As this event is very uncommon when implanting phakic intraocular lenses, the performed surgical procedure, the appearance of the vacuoles and the hypothesis on the origin of the vacuoles is described.

Refractive surgery with phakic intraocular lenses (pIOL) is a solution for young patients with clear lenses. The development of significant lens opacities after the insertion of these lenses are a complication that should be kept in mind. The incidence of cataractogenesis described after the implantation of posterior chamber pIOL ranges between 25.7% and 3.6% depending on the model of pIOL1. The suggested etiology for the development of cataracts are: intermittent contact between pIOL and the lens, operative trauma, insufficient lens nutrition and chronic subclinical inflammation. Anterior subcapsular cataracts are the most common type of cataract. These cataracts may either remain stable over time or lead to a reduction in visual acuity, and as such, these patients should undergo closer follow-up2.

The present work describes the case of a patient scheduled for the removal of a toric implantable collamer lens (ICL) from her right eye and the insertion of a new non-toric ICL due to the persistent rotation of the former. Reposition in accordance with the correct astigmatism axis was attempted twice, however, after both procedures, the ICL appeared to be misaligned in the days following. During the fourth surgical procedure, when the toric ICL was removed, vacuoles appeared on the surface of the patient´s lens. The surgical procedure performed and the evolution of the vacuoles is also described.

Leer más
Canadian Journal Ohpthalmology - Febrero 2015

Edena corneal transitorio en flap LASIK tras de cirugía de catarata

Canadian Journal Ohpthalmology - Febrero 2015

Artículo original publicado en:
Canadian Journal of Ophthalmology
Autores: Juan Gros-Otero, Montserrat García-González, Miguel A. Teus.

 

Abstract:

Estudios previos han demostrado que la cirugía LASIK induce cambios a largo plazo en el colgajo corneal1, la interfaz de LASIK2, y en la cama estroma residual3. En estudios publicados por Dawson et al4 han reportado diferentes comportamientos hidráulicos entre lecho estromal y el colgajo LASIK en un banco de córneas humanas, en 2 modelos experimentales de síndrome de fluido interfaz.

Presentamos un caso de edema corneal transitorio en flap LASIK trás cirugía de catarata. Este caso confirmaria, in vivo, el compartamiento hidráulico diferente del colgajo de LASIK en comparación con el lecho estromal y el resto de la córnea.

Leer más
Visión y Conducción (III Jornadas AEOPTOMETRISTAS)

Visión y Conducción – Revisión Legislación vigente

Visión y Conducción (III Jornadas AEOPTOMETRISTAS)

Revisión sobre la legislación vigente relacionada con la Visión y la Conducción presentado por Patricia González Rodríguez, optico-optometrista de Clínica Rementería, durante la III Jornada AEOptometristas celebrada en Madrid del 21 al 22 de febrero de 215.

Leer más